AXIS#.FAULT7016.ACTION

Description

This parameter determines the action the drive should take when F7016 occurs. If it is set to 1 or 4, the velocity will still be clamped at AXIS#.VL.LIMITP.

Parameter Value Drive Action
0 Disable Amplifier
1 Ignore (Fault will not be reported)
2 Controlled Stop
3 Dynamic Brake
4 Generate Warning (See W7016)

Versions

Action Version Notes
Implemented 02-10-04-000

General Information

Type

Read/Write

Units

N/A

Range

0 to 4

Default Value

1

Data Type

Integer

Stored in Non-Volatile Memory

Yes

Variants Supported

AKD2G

Fieldbus Information

EtherCAT CoE and CANopen

Command

Index

SubIndex

Data Type

Units

Float Scale

Access

PDO Mappable

AXIS1.FAULT7016.ACTION

501ch

03h

Unsigned8

-

-

Read/Write

No

AXIS2.FAULT7016.ACTION

511ch

03h

Unsigned8

-

-

Read/Write

No

EtherNet/IP

Name

ID

Hex

Data Type

Access

Units

AXIS1.FAULT7016.ACTION

7202

1C22

Unsigned8

Read/Write

-

AXIS2.FAULT7016.ACTION

72738

11C2

Unsigned8

Read/Write

-

PROFINET

Parameter

PNU

Data Type

Access

Units

AXIS#.FAULT7016.ACTION

7202

Unsigned8

Read/Write

-